Supplier Homepage Product Pulse Oximeter Hand-held Type Oximeter Handheld Pulse Oximeter SpO2 Sensor - CE and FDA (PM60A)

Handheld Pulse Oximeter SpO2 Sensor - CE and FDA (PM60A)

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Beijing, China
Transport Package: Carton
Payment Terms: T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Product Catalog
Pulse Oximeter
10 Products
Content
Product Image
Product Name
FOB Price
Port
Payment Terms
Product Table
Basic Info
  • Model NO.: PM60A
  • Type: Pulse Oximeter
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: Jxzz20142210338
  • Trademark: CONTEC
  • Origin: China
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, FDA, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Certificate: CE
  • Specification: CE
Product Description
Handheld Pulse Oximeter SpO2 Sensor - CE and FDA(PM 60A)

Instructions
Principle of the PM60A Patient Monitor is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology, the Patient Monitor can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.


Main performance

1.Display Mode: 3.5" Color TFT display
2.Screen Resolution: 320*240
3.SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
4.Accuracy: 70%~100%: ± 2%, Below 70% unspecified.
5.PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
6.Accuracy: ± 2bpm or ± 2% (select larger)
7.Measurement Performance in Weak Filling Condition:
8.SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
9.Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
10.Power Consumption: Less than 300mA
Voltage: DC 5.0V
11.Power Supply: Built-in recharge Li-Polymer
12.Battery working hour: 7 hours
13.Safety Type: Interior Battery, BF Type


Accessories

Sell in standard:
1.A user manual
2.A power adapter (GTM41076-0605; CMS0105)
3.A data line
4.A bracket
5.A disk (PC software)
6.An oximeter probe

Sell in addition:
Other oximeter probe(Refer to probe application instruction for details and notice renewal)

Physical Identity
Dimension: 92(W)x82(H)x22(D)mm
Weight: About 136g(with battery)

Qualification
Passed CE

Handheld Pulse Oximeter SpO2 Sensor - CE and FDA (PM60A)