Description | Vital Signs Monitor Patient Monitor with Touch Screen |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: single-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s |
HR: | Measurement and alarm range: 15~350 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2 mV ~ +2 mV Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes |
RESP | Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 12.5 mm/s, 25 mm/s |
NIBP | Method: Oscillometry Mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 minutes Measurement period in Continuous mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg |
SpO2 | Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified |
PR | Measurement and alarm range: 30 ~ 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater |
TEMP |
1.How many waveforms can be displayed on the screen?
The screen can display up to a maximum of 10 waveforms.
2. What types of batteries are used?
It uses built-in rechargeable lithium battery.
3.How many kinds of languages can it support?
Chinese, Englisn and Spanish.
4.How about the supply time?
At least 7 hours when the monitor without internal CO2 module is powered by new fully-charged batteries at 25°C with factory default screen brightness, Wi-Fi disabled, ECG and SpO2 cable connected, and auto NIBP measurements at an interval of 15 minutes.
5.How is charging time?
90 %: about 6 hours, fully charged: 8 hours
6.What can the Multi-function Interface be used for?
A It can be used as a nurse call interface. When connected with the hospital's call system, if an alarm occurs, it can output the nurse call signal to remind the nurse.
B It can be used as ECG analog signal output interface to output analog signal for oscilloscope and other equipment.
C It can be used as communication interface to communicate with external equipment.
7.What is the device working life?
10 years.