Contec NIBP Monitor Detection Medical Equipment Diagnosis Machine
Model:MS200 Brand:CONTEC

Introduction
It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor.
Functions
1) Pressure leak test
2) Over-pressure relief test
3) BP simulation under standard condition
4) BP simulation under patient condition
5) BP simulation under arrhythmia condition
6) BP simulation under respiratory interference condition
7) BP simulation of neonate
8) Wrist BP simulation
9) User-defined BP simulation
10) System setting function.
11) The parameters set can be stored.
12) ON/OFF function
13) Dynamic BP simulation
Performance
1.BP simulation range:
Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg)
Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg)
Pulse volume: 0.1 cc ~ 2.4 cc
HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm
HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)
Under patient condition:
Weak pulse, tachycardia, obese, geriatric: ±(preset value 1%+1)bpm
Moderate exercise: ±(preset value 1.5%+1)bpm
Strenuous exercise: ±(preset value 3%+1)bpm
2.Repeatability
Repeatability of blood pressure display(SYS,DIA):≤2.25mmHg
3.Pressure measurement:
Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg)
Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.01 psi
Accuracy:
0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg
40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading
4.Pressure leak test
Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds.
5.Over-pressure relief test
Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure.
6.Pressure source:
Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg)
Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.01 psi
Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc
7.Airtightness
Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under "OFF" state
Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min)
8.BP simulation preset value configuration table
| BP simulation | BP preset value | BP | HR | Pulse volume |
| Standard BP simulation | #1 | 120/80(93) | 80bpm | 0.68cc |
| #2 | 150/100(117) | 0.65cc | ||
| #3 | 200/150(167) | 0.60cc | ||
| #4 | 255/195(215) | 0.55cc | ||
| #5 | 60/30(40) | 0.75cc | ||
| #6 | 80/50(60) | 0.71cc | ||
| #7 | 100/65(77) | 0.69cc | ||
| BP simulation under patient condition |
Healthy heart | 120/80(93) | 75bpm | 0.68cc |
| Weak Pulse | 110/80(90) | 95bpm | 0.50cc | |
| Mild Exercise | 140/90(107) | 120bpm | 1.00cc | |
| Strenuous Exer | 140/90(107) | 162bpm | 1.40cc | |
| Obese | 120/80(93) | 90bpm | 0.50cc | |
| Geriatric | 150/110(123) | 95bpm | 0.40cc | |
| Tachycardia | 120/105(110) | 130bpm | 0.40cc | |
| Bradycardia | 120/60(80) | 45bpm | 1.10cc | |
| BP simulation under arrhythmia condition |
Premature Atrial Contraction1 | 138/53(81) | 80bpm | 0.70cc |
| Premature Atrial Contraction2 | 144/64(91) | 83bpm | ||
| Premature Ventricular Contraction | 118/61(80) | 83bpm | ||
| Atrial Fibrillation and PVC | 139/72(94) | 91bpm | ||
| BP simulation under respiratory interference condition |
spontaneous breathing1 | 138/65(89) | 104bpm | 0.60cc |
| spontaneous breathing2 | 149/65(93) | 105bpm | ||
| spontaneous breathing3 | 112/47(69) | 86bpm | ||
| controlled breathing | 132/44(73) | 98bpm | ||
| BP simulation of neonate |
#1 | 35/15(22) | 120bpm | 0.11cc |
| #2 | 60/30(40) | 0.10cc | ||
| #3 | 80/50(60) | |||
| #4 | 100/70(80) | |||
| BP simulation of wrist cuff |
#1 | 120/80(93) | 80bpm | 0.50cc |
| #2 | 160/100(120) | |||
| #3 | 80/55(63) | |||
| User-defined BP simulation[1] | - | - | - | - |
Note[1]:Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume ≤ 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm).






Q: Are you manufacturer or reseller?
A: We are manufacturer which specialized in developing, manufacturing and distributing medical device Since 1996.
Q: Where your factory located in? How can I visit it?
A: Our factory located in Qinhuangdao city, Hebei Province, P.R.China, about 2 hours by train from Beijing. We warmly welcome for your visiting!
Q: Do you support customization? such as provide box according to my design or print my logo on the gift box or device?
A: Of course, we support OEM/ODM service. we can help design box according to your requirement. Moreover, we can also make mould to provide device with different appearance.
Q: How can i place an order?
A: You can place order directly or contact us to draft order and send you payment link; we can also issue invoice for you to pay by TT/Paypal/LC/Western Union etc.
Q: How many days for shipping after payment done?