Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ECG | Multi-parameter Portable Cardiac Patient Monitor |
Lead selection: I, II, III, aVR, aVL, aVF, V | |
Waveform: 5-lead, dual-channel | |
3-lead, single-channel | |
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV | |
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s | |
HR: | Measurement and alarm range: 15~350 bpm |
Accuracy: ±1 % or ±1 bpm, whichever is greater | |
Alarm accuracy: ± 2 bpm | |
Resolution: 1 bpm | |
ST-segment monitoring: | |
Measurement and alarm range: -2.0 mV ~ +2.0 mV | |
Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater | |
Other range: unspecified | |
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, | |
PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC | |
Pacemaker: yes | |
RESP | Method: R-F(RA-LL) Impedance |
Respiration rate:Measurement and alarm range: 0~150 rpm | |
Resolution: 1 rpm | |
Measurement accuracy: ±2 rpm | |
Alarm accuracy: ±3 rpm | |
Apnea alarm: 10~40s | |
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s | |
NIBP | Method: Oscillometry |
Mode: Manual/AUTO/STAT | |
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes | |
Measurement period in STAT mode: 5 minutes | |
Measurement and alarm range: 10 ~ 270 mmHg | |
Resolution: 1 mmHg | |
Cuff pressure accuracy: ±3 mmHg | |
Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg |
|
Spo2 | Measurement and alarm range: 0 ~ 100% |
Resolution: 1% | |
Measurement accuracy: 70%~100%: ±2%; | |
0%~69%: unspecified | |
PR | Measurement and alarm range: 30 ~ 250 bpm |
Measurement accuracy: ±2 bpm or ±2%, whichever is greater | |
TEMP | Channel: dual-channel |
Measurement and alarm range: 0 ~ 50ºC | |
Resolution: 0.1 ºC | |
Accuracy: ±0.1 ºC | |
EtCO2 | Method: Sidestream or Mainstream Measuring Range: 0~150mmHg |
Resolution:0~69 mmHg, 0.1 mmHg 70~150 mmHg, 0.25 mmHg |
|
Accuracy:0~40 mm Hg ±2 mm Hg 41~70 mm Hg ±5% 71~100 mm Hg ±8% 101~150 mm Hg ±10% |
|
AwRR Range: 2~150 rpm | |
AwRR Accuracy: ±1BPM | |
Apnea Alarm: Yes | |
IBP | Channel: dual-channel |
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 | |
Measuring and Alarm Range: -10~300 mmHg | |
Resolution 1 mmHg | |
Accuracy: ±2% or 1mmHg, whichever is greater | |
Power supply: 100-240V~, 50/60Hz | |
Safety classification: Class I, type CF defibrillation-proof applied part |