• Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
  • Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
  • Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
  • Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
  • Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
  • Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator

Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator

Classification: ECG Simulator Multi-Parameter Patient Ecgsimulator
Type: ECG Simulator Multi-Parameter Patient Ecgsimulator
Certification: CE, ISO13485
Group: ECG Simulator
Product Name: ECG Simulator
Warranty: 12 Month for Main Unit
Customization:
Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory, Other
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
MS400
Display
3.5′′ TFT Touch Screen
Battery
Rechargeable Lithium Battery
Transport Package
Carton
Specification
18.86 cm(L)& 12.50 cm(W)& 4.32 cm(H)
Trademark
Contec
Origin
Hebei, China
HS Code
8543201000
Production Capacity
500/Week

Product Description

Ms400 ECG, Arrhythmia, IBP, Respiration Multi-Parameter Patient ECG Simulator

Product Description


Model:MS400           Brand:CONTEC
Introduction
Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient SimulatorContec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator

MS400 Multiparameter Simulator(ECG simulator) is a portable device, can simulate accurately 12-lead ECG, Respiration, Temperature,2-channel IBP or 4-channel IBP, the default is 4-channel IBP. 
Project Name Description
1 IBP1 port  Used to connect IBP1 cable plug. (Refer to "IBP Line Orders")
2 IBP2 port  Used to connect IBP2 cable plug. (Refer to "IBP Line Orders")
3 IBP3 port  Used to connect IBP3 cable plug. (Refer to "IBP Line Orders")
4 IBP4 port  Used to connect IBP4 cable plug. (Refer to "IBP Line Orders")
5 C.O./TEMP port The port is temperature port at present.
Note: if you use this port, plugged the body temperature cables before turned on the simulator.
6 USB port  Reserved port 
7 Reset port Switch the simulator.
8 TF port Plug SD card.
Note: If use the SD card, you need to put the SD card into the simulator before turning it on. 
9 Equivalent power jack According to the instructions of our company's power supply.
10 10-lead jacks Output to 10 Universal ECG Jacks, color-coded to AHA and IEC Standards.
Label Meaning
RA or R  Right arm
LA or L Left arm
RL or N  Right leg(reference or grounded)
LL or F Left leg
V1, V2, V3, V4, V5 and V6  V Leads (U.S. and Canada), also referred to as pericardial, precordial or unipolar chest leads.
C1, C2, C3, C4, C5 and C6 Chest leads (International)
11 The indicator light
 of charging
Charge indicator light is red : AC power supply / charging. Green : full electricity.
Red and flashing: battery low.
12 Display The display shows the selected code, the meanings of the code, the waveforms, the list of the functions, System Setting and so on.
13 Keys There are two kinds of keys: the numeric keys and function keys. 
0 View the current settings.
1 Normal sinus rhythm, 80BPM, 1mV.
2 Set the ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM.
3 Set amplitude: 0.5, 1.0, 1.5 and 2.0 mV.
4 Set the respiratory Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80,100, 120 and 150 R/MIN.
5 Set the baseline impedance : 500, 1000, 1500 and 2000Ω.
6 Set the respiratory impedance : 0.2, 0.5, 1.0 and 3.0 Ω.
7 Channel 1, 2,3 and 4 will be reset to 0.
8 Set all the channels as IBP waveform.
9 Set all the channels as static-pressure level.
14 Control keys   
Up and down keys When select a key which can adjust a setting, you can click the up and down keys to adjust it.
Left and right keys Switch the pages and browse the codes.
Enter Determine the choice.
CLEAR Cancel the current selection, select the code again.
On/Off Long press the key to turn on or turn off the simulator.
 

Main Features
ECG:
1.Conventional: All leads have the same voltage with the II-lead as the reference
2.Amplitude: 0.5, 1.0, 1.5 and 2.0mV
3.ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
4.ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
5.The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV

Arrhythmia:
1.ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
2.Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
3.Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
4.Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block


Four IBP Channels:
1.The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge  10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
1.Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
2.Man Swan-Ganz: press ENTER key to change every time
3.Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3

Respiration:
1.Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
2.Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
3.Baseline impedance: 500, 1000, 1500, 2000Ω
4.Apnea: 12 s, 22 s, 32 s

Temperature:
Four temperature: 0ºC(32°F), 24ºC( 75°F), 37ºC(98.6°F), 40ºC(104°F)

Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.
 
Item Quantity
Standard components:
User Manual (print version) 1
15V adapter or 9V adapter ( USA Porduction) 1
Optional Accessories:
Temperature Cable 1
IBP Cable 1
Case Convertion Software and Operating Introduction 1
For more information, please contact your local dealer.


Packaging & Shipping
 30*19*10(cm)   1.2 KG
Delevery:within 5-10 working days after payment is confirmed by our company.
  
Our Services
Warranty: 18-month for main unit,6-month for accessaries
Technical support

Company Profile


Contec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient SimulatorContec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient SimulatorContec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient SimulatorContec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient SimulatorContec Ms400 ECG/Arrhythmia/IBP/Respiration Multi-Parameter Patient Simulator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now