Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: ECG
Manufacturer/Factory, Other

360° Virtual Tour

Diamond Member Since 2008

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 125 foreign trading staff(s) and 73 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO 13485:2016
to see all verified strength labels (36)
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
  • Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
ECG1212G
Product
12 Channel Electrocardiograph ECG Monitor
Channel
12
Warranty
One Year
Product Name
12 Channel ECG Machine
Display
10.1′′ High-Resolution Color LCD
Transport Package
Carton
Specification
ISO13485
Trademark
CONTEC
Origin
China
HS Code
9018110000
Production Capacity
5000PCS/ Week

Product Description

Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
Product Description

Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
Introduction

The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for "Lead off" and "Lack of paper"; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.
 
Functions
1)Adopt 10.1'' high-resolution color LCD, operate by full-touch screen and function bu ttons, convenient to use.
2)Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 / 60 Hz), baseline filter and EMG filter (25 / 35 Hz) of ECG signal.
3)Display 3 / 6 / 12 - lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, clock, battery power, background grid, measured parameter and interpretation, etc. on one screen, and with prompt functions for lead - off, overload and system working state.
4)Power supply: AC / DC (which can adapt AC 50 / 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
5)In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.
6)Built-in thermal printer, support multiple printing modes and formats, such as, auto M × N, M × N + 1, M × N + 2, rhythm M line and manual, etc. The contents including time, paper speed, sensitivity, calibration signal, lead name, filter state and patient information can be printed. The waveform length printed, measurement parameter output, diagnosis conclusion, superimposed QRS waveform, histogram, trend chart and interval list, etc. can be set. With the print functions (timing print and auto-print for arrhythmia, etc.), which meet different requirements.
7)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measured results and auto-diagnosis conclusions for HR, PR interval, P Duration, QRS Duration, QT / QTc interval, P / QRS / T Axis, R (V5), S (V1), R (V5) + S (V1) amplitude, etc. which reduces the doctor's burden.
8)Built-in memory stores 4000 cases (data saving time: 10 s) at least, convenient for case review and statistic.
9)Historical cases can be reviewed, inquired, modified, transmitted, printed, lead corrected, the cases can also be exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, etc.)
10)Chinese / English operating interface, the report in corresponding language can be printed; built-in virtual keyboard, support Chinese / English input method.
11)Support external USB standard keyboard, mouse, scanner and printer.
 
Performance
1)Input mode: floating and defibrillation protection
2)Lead: standard 12-lead
3)Patient leak current: < 10 µA
4)Input impedance: ≥ 2.5 MΩ
5)Frequency response:
Nominal input amplitude Input frequency and waveform Relative output response
1.0      0.67 Hz ~ 40 Hz, sinusoidal      ±10 %a
0.5  40 Hz ~ 100 Hz, sinusoidal    +10 %, -30 %a
0.25   100 Hz ~ 150 Hz, sinusoidal     +10 %, -30 %a
0.5       150 Hz ~ 500 Hz, sinusoidal +10 %, -100 %a
1.5    ≤1 Hz ,200 ms, triangular         +0 %, -10 %b
  a relative to 10 Hz output   b relative to 200 ms output

6)Time constant: ≥ 3.2 s
7)CMRR: > 105 dB
8)Filter: power frequency (AC 50 / 60 Hz), EMG (25 Hz / 35 Hz (-3 dB)) and baseline drift
9)Recording mode: thermal printing system
10)Paper size: 210 mm (W) × 20 m (L), high-speed thermal paper
11)Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 %
12)Gain (sensitivity): 5, 10, 20 mm / mV, accuracy: ± 2 %
     Standard sensitivity: 10 mm/mV ± 0.2 mm/mV
13)Record mode: auto, rhythm and manual record
14)Measurement parameters: HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude
15)Safety class: class I, defibrillation-proof type CF applied part
16)Polarizing voltage: ± 610 mV
17)Noise level: ≤ 12 µVp-p
18)Sampling frequency for ECG signal input: 32 kHz
19)Sampling frequency for waveform data processing: 1 kHz
20)Sampling accuracy: 24 - bit
21)Minimum detection signal: a 10 Hz, 20 µV (peak - peak value) sinusoidal signal can yield a visual recorded deflection.
22)Pacemaker detection channel: II
23)Accuracy of input signal reproduction: ± 5 %
24)Amplitude quantization: ≤ 5µV/LSB
25)Time deviation in each channel: <100 µs
26)Power supply:
AC: 100V ~ 240V (50 / 60 Hz)
DC: 14.8 V / 5200 mAh rechargeable lithium battery
27)Degree of protection against ingress of liquid: IPX0
28)Working mode: continuous operation
 
Accessories
Standard:
One lead cable
One limb electrode
One chest electrode
One thermal recording paper
One power cord
One earth wire
One User Manual
 
Physical characteristic
Operating:
a) Environment temperature: 5 ºC ~ 40 ºC
b) Relative humidity: 25 % ~ 95 % (non - condensing)
c) Atmospheric pressure: 700 hPa ~ 1060 hPa
Transport and storage:
a) Environment temperature: - 20 ºC ~ + 55 ºC
b) Relative humidity: ≤ 95 %
c) Atmospheric pressure: 500 hPa ~ 1060 hPa
Dimension: 340 mm (L) × 320 mm (W) × 86 mm (H)
Weight: 5 kg
Company Profile

 

Contec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG MachineContec ECG1212g 12 Channel Electrocardiograph Touch Screen Monitor ECG Machine
FAQ

Q: Are you manufacturer or reseller? 
A: We are manufacturer who has more than 25 years experience on research & design, production and sale.

 
Q: Where your factory located in? How can I visit it? 
A: Our factory located in Qinhuangdao city, Hebei Province, P.R.China, about 2 hours by train from Beijing. We warmly welcome for your visiting!
 
Q: Do you support customization? such as provide box according to my design or print my logo on the gift box or device?
A: Of course, we support OEM/ODM service. we can help design box according to your requirement. Moreover, we can also make mould to provide device with different appearance.
 
Q: How can i place an order? 
A: We support alibaba trade assurance order, you can place order directly or contact us to draft order and send you payment link; we can also issue invoice for you to pay by TT/Paypal/LC/Western Union etc.
 
Q: How many days for shipping after payment done?
A: Sample order will be sent within 2 days after receiving sample fee. 3-20 days for general order according to the quantity. Customized order need mutual negotiation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier