OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard

Product Details
Customization: Available
Transport Package: Carton
Trademark: CONTEC

Industry-leading Audited Factory

Diamond Member Since 2008

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 125 foreign trading staff(s) and 73 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO 13485:2016
to see all verified strength labels (36)
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
  • OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
CONTEC08E Mainboard
Origin
China

Product Description

OEM/ODM Medical Module Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard Independent R&D Customizable Bluetooth.
Product Description

OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard
General purpose motherboard 

(board card assembly)
The motherboard can measure blood pressure through an external cuff. The button function can realize one-button blood pressure measurement, and the data are collected and calculated through the step decompression technology algorithm, and finally the measured data are presented on the 4.6inch LED display screen; the whole measurement process is guided by human voice and broadcast the data, and the upgraded clinical algorithm ensures the reliability of the data. In addition, the motherboard expands the real-time clock function, which can configure the time. After configuration, the system automatically records the measuring time of each group of values.

Product features
1. The principle of oscillatory method is step outgassing measurement, the collection is accurate and the data is reliable.
2. Irregular pulse wave prompt function, prompt when the pulse interval is irregular in the process of measurement.
3. Cuff wear self-test prompt, cuff binding is not standard prompt function.
4. Diversified products to meet the needs of users.
5. Low power reminder, error message prompt, rich information.
6. Support for automatic recording of measurement data.
7. Live voice broadcast, audible guidance for the whole process.
8. Feature-rich, highly integrated and easy to operate.
9. In line with the general and special standards of medical equipment at home and abroad.
10. Superior performance, reliable and stable.


Product parameters
 Motherboard:
Human-computer interaction (input) Memory button-for users to query survey records.
Start / end button-turn on measurement mode
Human-computer interaction (output) LED display-real-time feedback of measurement information.
Voice broadcast-full broadcast voice prompt
Interface description SOUND- speaker interface, real-time broadcast.
POWER- internal power interface, can realize battery mode power supply.
DCPOWER- external power interface, which can realize adapter mode power supply.
PUMP- air pump interface to drive the air pump to achieve the function of inflating to the outer cuff.
VALVE- air valve interface to drive the air valve to realize the venting function.
Pressure sensor interface-connected to the external cuff through the air path to achieve real-time pressure acquisition function

Environment description
Working environment Storage environment
Temperature:+5%~40ºC  Temperature:-20ºC~+55ºC
Humidity:15%RH~85%RH(No condensation)    
Humidity: not more than 95%, non-corrosive gas environment
Precision Static pressure:±3mmHg(±0.4kPa)
Measuring range High pressure:30~270mmHg(4~36kPa)
Low pressure:10~220mmHg(1.3~29.3kPa)
Pulse rate:40~240/min
Pressure range 0~297mmHg(0~39.6kPa)
 
Company Profile

 

OEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor MainboardOEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor MainboardOEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor MainboardOEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor MainboardOEM/ODM Independent R&D Customizable Electronic Sphygmomanometer Motherboard Blood Pressure Monitor Mainboard